How to verify an Electrician CV — official standards
Electrician CVs are difficult to compare because the job title says almost nothing about scope. "Electrician" can mean pulling cable on a construction site, commissioning low-voltage installations under HD 60364, working live under the rules of EN 50110-1, or testing appliances to EN 50678 / EN 50699. When candidates apply across borders, the qualification names change too: a Slovenian NPK Elektroinštalater, a German Geselle or Meister, or a vocational diploma placed somewhere on EQF levels 1–8.
The standards themselves are documented and checkable. HD 60364 (IEC 60364, in Germany VDE 0100) governs LV installations, with Part 6 requiring verification by measurement. EN 50110-1 defines who may do what: skilled, instructed or ordinary person. A rigorous check means reading the CV against these references, asking for the documents behind each claim, and confirming whether the role is regulated in your country via Directive 2005/36/EC and the RegProf database. WorkerProof verifies documents and claims — it does not grant recognition.
What a strong CV must contain
A strong CV names the framework the candidate worked to: HD 60364 / IEC 60364 for LV installations, EN 50110-1 for safe operation, EN 62305 where lightning protection was involved. Generic phrasing like "installation and maintenance" tells you nothing about scope.
Part 6 of HD 60364 requires verification by measurement: insulation resistance, fault-loop impedance and RCD tests. Look for these named explicitly, plus the instruments used and who signed off the results.
EN 50110-1 distinguishes skilled, instructed and ordinary persons and sets out the five safety rules before work. The CV should state which role the candidate held, and whether they were authorised for live working conditions.
Ask for the qualification name plus its level: NPK Elektroinštalater (SI), German Geselle (EQF 4) or Meister (EQF 6), or a vocational diploma with the awarding body named. Without an EQF reference, national titles are hard to compare.
If the candidate claims equipment testing, expect EN 50678 (after repair) or EN 50699 (recurring periodic tests) — protective conductor, insulation and leakage current measurements. In the German market this appears as DGUV V3 / VDE 0701/0702 testing.
ESCO lists installing electric switches and electricity sockets, using precision tools, using safety equipment in construction, working ergonomically and resolving equipment malfunctions. A useful CV shows where and on what type of installation these were done.
⚠️ Red flags to watch for
Questions to ask the candidate
- 01Which parts of HD 60364 / IEC 60364 did you work to, and on what type of low-voltage installation?
- 02Walk me through a verification to HD 60364-6: which measurements did you take — insulation resistance, fault-loop impedance, RCD tests — and with which instrument?
- 03Under EN 50110-1, were you classified as a skilled, instructed or ordinary person, and can you list the five safety rules you applied before starting work?
- 04Have you tested electrical appliances to EN 50678 (after repair) or EN 50699 (recurring tests), and which measurements did the test protocol include?
- 05What is the exact name, issuing body and EQF level of your qualification — for example NPK Elektroinštalater, Geselle or Meister — and can you provide the certificate?
The official standards behind the score
WorkerProof checks every CV against this verified matrix.
- HD 60364 / IEC 60364 series
- EN 50110-1 (operation of installations)
- HD 60364-6 (verification)
- EN 50678 / EN 50699
- NPK Elektroinštalater (SI)
- Elektrofachkraft / VDE practice (DE)
Frequently asked questions
Which standards should an Electrician CV refer to?
For low-voltage installations, the HD 60364 / IEC 60364 series, with HD 60364-6 covering verification by measurement. EN 50110-1 covers safe operation of installations, EN 50678 / EN 50699 cover testing of electrical appliances, and EN 62305 applies to lightning protection systems.
Is the electrician profession regulated in the EU?
Some electrical roles are regulated in some countries. Directive 2005/36/EC sets out the EU system for recognising professional qualifications, and the Commission's RegProf database lists where a given profession is regulated. Recognition itself is decided by the host country's competent authority — not by an employer or by WorkerProof.
How do I compare a foreign electrician qualification with a local one?
Use the European Qualifications Framework, which places national qualifications on levels 1–8. A Slovenian NPK or vocational diploma, a German Geselle (EQF 4) or Meister (EQF 6) can be placed on the same scale, which makes documents comparable — though comparison is not the same as legal recognition.
What evidence proves that a candidate can carry out installation verification?
HD 60364-6 requires verification by measurement, so ask for evidence of insulation resistance, fault-loop impedance and RCD testing. Test protocols, handover documentation or an employer reference naming these measurements are stronger evidence than a skills list.
What does WorkerProof actually check on an Electrician CV?
WorkerProof reads the CV against the official standards matrix for ISCO 7411 — HD 60364 / IEC 60364, EN 50110-1, HD 60364-6, EN 50678 / EN 50699, EN 62305 — and against ESCO skills for the trade, and flags claims that lack supporting documents. Each CV is verified 3×. WorkerProof verifies documents and claims; it does not grant or confirm legal recognition of qualifications.